- Illumination 130,000 lux
- Color Temperature 3,500 K
- Color Rendering Index 95 Ra
- The system is a light-gathering system with glass and micro-lenses
- Halogen bulbs / LED bulbs (Ambient Light)
- Light PATTERN 26 -30 CM.
Medical compressed air generator AIR COMPRESSOR SYSTEM
The SILBERMANN medical gas control panel supplies adjustable pressure, as required, to pneumatic-driven surgical tools in the operating theaters.
Silbermann’s gas control panel is designed to meet the latest and most rigid American NFPA99 and European EN ISO 7396-1 requirements
Features
Medical Gas System Standards:
Silbermann’s Quality Management System:
An innovative 12” touch screen area & main alarm panel monitors and displays the local & remote (Manifold Systems) medical gas information as required by the latest additions of NFPA99, EN ISO 7396-1 and HTM02-01.
The new Silbermann touch screen alarm panel incorporates state of the art Hi security technology, protecting the information displayed and transmitted, from malicious attacks
Features
Applicable Standards
Ceiling Mounted Flexible Hoses are used for delivering gas through a retractable hose in large rooms like OT’s.
On one end, this hose assembly is connected to the ceiling gas outlet with a DISS/Nist fitting that is suitable for the required gas type. On the other end, it is connected to a portable gas outlet that has the same gas coding as the ceiling outlet.
A pulley (key back) is attached to the hose to easily adjust its height according to the user’s needs.
Features
Technical Data
Medical Gas System Standards:
Applicable Standards:
Silbermann’s Quality Management System:
* Other types of portable outlets are available by customers’ request
Pressure resistant rubber tubing for medical gas systems
Clean air supply panel set for operating rooms with LAMINAR FLOW SUPPLY AIR PLENUM WITH LOW TURBULANCE DISPLACEMENT FLOW
The clean air supply panel set is designed for use in operating rooms that require high cleanliness and has a smooth air supply characteristic with an air velocity of approximately 0.25 M/S (LAMINAR FLOW). It is installed in areas of the operating room that require high cleanliness to prevent infection (PROTECTION CLEAN ZONE) according to the standards EN ISO 14644-1, ONORM H 6020, DIN 1946 and VDI 2083. The clean air supply panel consists of
Technical Features
Note: MARCHHART brand product, AUSTRIA, model LF-ZP 2.4 x 2.4
High-clean air conditioning system meets the criteria and standards for hospitals according to ASHRAE Application Handbook 2003. Health Care Facilities.
Clean air distribution panel set LARMINAR AIR FLO LARMINAR AIR FLOW