Products Medical Gas
Service Outlet

Ceiling Mounted Flexible Hoses are used for delivering gas through a retractable hose in large rooms like OT’s.

On one end, this hose assembly is connected to the ceiling gas outlet with a DISS/Nist fitting that is suitable for the required gas type. On the other end, it is connected to a portable gas outlet that has the same gas coding as the ceiling outlet.

A pulley (key back) is attached to the hose to easily adjust its height according to the user’s needs.

Features

  • A quick connect outlet with flexibility in use – you can pull the hose down with its connecting adapter and then release it, to move back to its original place.
  • Cost-effective – alternative for using pendants in OTs.
  • Fits for rooms where it is difficult to install outlets in the side walls.

Technical Data

  • Hose length:
    • maximum extension – 1.65 m
    • retractable position – 1.20 m
  • Available for all medical gases: Oxygen, Vacuum, Medical Air, Nitrous-Oxide N2 and Co2.
  • Portable gas outlets that can be attached to the hose are available in several standards including DIN, ENV, Sil-Ohio, Puritan Bennett, Chemetron, and British standard*.
  • Retractable hoses work with a pulley (key back).
  • Each medical gas outlet and hose has a gas coding to avoid inappropriate gas usage.

Medical Gas System Standards:

  • NFPA 99, EN ISO 7396-1 & GO-1, HTM 02-01 requirements

Applicable Standards:

  • NFPA 99, ISO 9170-1, ISO 5359

Silbermann’s Quality Management System:

  • EN ISO 13485-2016, ISO 9001-2015

* Other types of portable outlets are available by customers’ request

The Silbermann jet scavenging inlet is designed for safe removal of surplus anaesthetic gas from the operating theatre.

The scavenging inlet assembly uses compressed air to create suction and propels the contaminated air to the outside atmosphere.

Features

  • Operation based on compressed air – No need for a central AGSS system
  • When probe is connected, green pneumatic indicator showing system is in use
  • Very quiet operation
  • Automatic shut off when probe is disconnected
  • Flow and vacuum adjustment
  • Locking mechanism quick connect

Medical Gas System Standards:

  • NFPA99
  • ISO 7396
  • G-01
  • HTM 02-01

Silbermann’s Quality Management System:

  • EN ISO 13485-2016
  • ISO 9001-2015
  • CE marked

We design and manufacture our Terminal Units to last and to ensure a
constant and reliable medical gas flow for the patient and the medical
equipment.

All outlets are 100% tested for flow, and leakage.
They are cleaned for oxygen services before shipping.
Our outlets are designed by industrial designers to ensure an appealing
and pleasant environment for the patient and the medical staff.

Features

  • Accepts Sil-Ohio (Diamond type) gas specific outlets.
  • All outlets are 100% hydrostatic tested for leaks. The outlets are factory assembled, degreased and cleaned for medical gas service.
  • Indexed to eliminate interchangeability of gas services.
  • 360 swivel inlet pipe for ease of installation.
  • Low maintenance due to use of VITON seals in front assembly (latch valve).
  • Modular singles – designed to provide ganging of rough-in modules in the field to form multiples at any order with 120mm spacing.

Medical Gas System Standards:

  • NFPA99, EN ISO 7396-1 requirements.

Applicable Standards:

  • NFPA99
  • ISO 9170-1.

Silbermann’s Quality Management System:

  • CE marked by the notified body TÜV-SÜD.

We design and manufacture our Terminal Units to last and to ensure a constant and reliable medical gas flow for the patient and the medical equipment.

All outlets are 100 % tested for flow, leakage and are cleaned for oxygen services prior to shipping

Features & Benefits

  • Accepts DISS gas specific adapters.
  • All outlets are 100% hydrostatic tested for leaks. The outlets are factory assembled, degreased and cleaned for medical gas service.
  • Indexed to eliminate interchangeability of gas services.
  • 360 swivel inlet pipe for ease of installation.
  • Safe plug-in & release allowing parking of male adapter on the outlet thread without pressure applied.
  • Low maintenance due to use of VITON seals in front assembly (latch value).
  • Modular singles – designed to provide ganging of rough-in modules in the field to form multiples at any order with 120mm spacing.

Medical Gas System Standards:

  • NFPA99, EN ISO 7396-1 & G0-1 requirements..

Applicable Standards:

  • NFPA99, ISO 9170-1, CGA-V5.

Silbermann’s Quality Management System:

  • EN ISO 13485-2016
  • ISO 9001-2015

The SILBERMANN medical gas control panel supplies adjustable pressure, as required, to pneumatic-driven surgical tools in the operating theaters.

Silbermann’s gas control panel is designed to meet the latest and most rigid American NFPA99 and European EN ISO 7396-1 requirements

Features

  • Compatible with Nitrogen or Industrial Air
  • Easy, safe and reliable connection between the medical equipment and the medical gas distribution system
  • Anodized Aluminum front with rounded edges for aesthetic appeal
  • Manual shut-off valve
  • Inlet & outlet pressure gauges
  • DISS or NIST outlet connection
  • A Knob to adjust outlet pressure

Medical Gas System Standards:

  • NFPA99, EN ISO 7396-1

Silbermann’s Quality Management System:

  • ISO 9001-2015
  • ISO 13485-2016
  • CE mark

Our Partner