Quick plug outlet for ceiling mounting
- Silbermann , Ohio Type consists of Primary and Secondary check valves with threaded connections The hose is 1/4? NPT for use with surgical supply line sets
Medical gas connector, quick connection to pipeline
The New Mazor-AU fully automatic changeover system is designed to meet the NFPA99, or EN ISO 7396-1, or HTM02-01 or G-01 standard.
The system manages 2 sources and provides continuous supply and smooth automatic bank switchover by means of pneumatic shuttle valve.
All medical gas information is displayed graphically and digitally on a 12” full HD LCD touch screen
Features & Benefits
Silbermann’s Quality Management System:
Valve box with a pull-out window and Valve box with an aluminium door
General Speciications
We design and manufacture our Terminal Units to last and to ensure a
constant and reliable medical gas flow for the patient and the medical
equipment.
All outlets are 100% tested for flow, and leakage.
They are cleaned for oxygen services before shipping.
Our outlets are designed by industrial designers to ensure an appealing
and pleasant environment for the patient and the medical staff.
Features
Medical Gas System Standards:
Applicable Standards:
Silbermann’s Quality Management System:
The door for the main operating room entrance (Main Door) is designed for use in the operating room as a sliding door, brand MARKUS, model M5 or MARKRONOMIC, which is a product of Europe or America. It has an opening size of 1,500 mm. x 2,100 mm. with a 300 mm. x 300 mm. glass window, it is a hermetic sealing system, HERMETIC SEALING SLIDING DOOR. The top and sides of the door edge are installed with RUBBER SEALING PROFILE rubber sheets and the bottom edge of the door is installed with STRIP RIGID RUBBER SEAL rubber edges along the line with door hanging rails. The sliding door runs on BALL RACES with NYLON wheels. The door handle is made of aluminum. The door opens and closes automatically controlled by a MICRO PROCESSOR MICRO PROCESSOR with elbow control switches (ELBOW SWITCH) and NO TOUCH SWITCH. There is a SINGLE – BEAM PHOTO – ELECTRIC CELL safety system. If there is an obstacle at the door, the door will stop and open automatically in case of malfunction of the automatic open-close set or power outage. The door can be opened-closed with the door handle. The door is about 40 mm thick and can prevent noise of about 27 decibels. The door frame is made of SATIN ANODIZED EXTRUDED ALUMINIUM SATIN ANODIZED EXTRUDED ALUMINIUM. The door surface is covered with PLASTIC PLASTIC LAMINATE. The door frame and door are finished products from the same manufacturer. The main entrance door to the operating room has been tested according to the air leakage prevention standard AIR PERMEABILITY TEST SLIDING DOOR ANSI / UL 1784 or BS 476.
Note: The product is a MARKUS or KONE brand from the Netherlands.
We design and manufacture our Terminal Units to last and to ensure a constant and reliable medical gas flow for the patient and the medical equipment.
All outlets are 100 % tested for flow, leakage and are cleaned for oxygen services prior to shipping
Features & Benefits
Medical Gas System Standards:
Applicable Standards:
Silbermann’s Quality Management System: